Configuration of 2 MWe IC Engine Based CHP System

 

Nexterra's next-generation power generation systems can provide clean, reliable syngas suitable for firing in high-efficiency internal combustion engines designed for stationary power/CHP applications. This high-efficiency power/CHP solution is ideal for District Energy Plants and Independent Power Producers where power prices are particularly high and where efficiency is a critical consideration. The first 2 MWe demonstration of this system was installed at the University of British Columbia in 2012. Nexterra also completed over 3,000 hours of operation of this system at a 239 kWe scale at its Product Development Centre.

  • Output: Power, Combined Heat and Power (CHP)
  • Systems Size: 2 to 10 MWe + 3 to 15 MWth (9 to 45 MMBtu/hr)
  • System Efficiency (HHV): Combined Cycle electrical 30%; CHP up to 60%
  • System Efficiency (LHV): up to 64% depending on fuel/project specifics
  • Fuel Types: Wood Residuals, Clean Construction Debris, Biosolids
  • Fuel Feed: 35 – 140 tonnes per day (bone dry)
  • Fuel Moisture Content: 6 – 60% moisture
  • Fuel Size: 7.5 cm (3 inches) or less in all dimensions
  • Projects: University of British Columbia (Demonstration)

Contact us to see if our power generation/CHP system is suitable for your needs.